Publications Repository - Helmholtz-Zentrum Dresden-Rossendorf
1 PublicationA simple method for deadtime corrections in microbeam measurements.
Munnik, F.
Abstract
In microbeam measurements on inhomogeneous samples large variations in count-rate can occur. These variations result in variations in deadtime that have to be used to correct elemental distribution maps. However, the deadtime is usually not available on a pixel by pixel basis. In this work, a simple model is proposed to calculate the deadtime for each pixel. Measurements to determine the deadtime per event, needed in the model, are presented and the deadtime corrections are presented for real samples.
Keywords: dead time; PIXE
Involved research facilities
- Ion Beam Center DOI: 10.17815/jlsrf-3-159
Related publications
- DOI: 10.17815/jlsrf-3-159 is cited by this (Id 21756) publication
-
Poster
14th International Conference on Particle Induced X-ray Emission (PIXE 2015), 26.02.-03.03.2015, Somerset West, South Africa
Permalink: https://www.hzdr.de/publications/Publ-21756