Publikationsrepositorium - Helmholtz-Zentrum Dresden-Rossendorf
1 PublikationPartilce-free cathode transfer system for SRF photoinjector
Xiang, R.; Gatzmaga, S.; Murcek, P.; Steinbrueck, R.; Teichert, J.; Arnold, A.; Hoffmann, A.
Abstract
Superconducting radio frequency (SRF) photoinjectors offer advantages for continuous wave (CW) operation and high brightness, high current beam generation. One of the critical components for successful operation of SRF photoinjectors is the photocathode system. HZDR is building a sophisticated cathode exchange system to ensure accurate, particle-free and warm cathode exchange. A novel alignment process aligns the cathode to the gun axis without touching the cathode plug itself. Less than 10 particles as small as 0.3 micrometer are detected
during the cathode load-lock tests.
Beteiligte Forschungsanlagen
- Strahlungsquelle ELBE DOI: 10.17815/jlsrf-2-58
- Superconducting Electron Linear Accelerator
- SRF Gun
Verknüpfte Publikationen
- DOI: 10.17815/jlsrf-2-58 is cited by this (Id 39137) publication
-
Vortrag (Konferenzbeitrag)
87. Jahrestagung der DPG und DPG-Frühjahrstagung der Sektion Kondensierte Materie (SKM) 2024, 17.-22.03.2024, Berlin, Germany
Permalink: https://www.hzdr.de/publications/Publ-39137
Jahre: 2023 2022 2021 2020 2019 2018 2017 2016 2015