Navi-Edit

Techniques
Not availableNot availableNot availableNot availableNot availableNot availableNot availableNaviEdit (7)
XRF
No permissionsNot availableNot availableNo permissionsNo permissionsNot availableNo permissionsNaviEdit (0)
SEM
No permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNaviEdit (0)
MLA
No permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNaviEdit (0)
XRD
No permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNaviEdit (0)
EPMA
No permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNaviEdit (0)
Super-SIMS
No permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNo permissionsNaviEdit (0)
3D X-ray CT
No permissionsNo permissionsNo permissionsNot availableNot availableNo permissionsNo permissionsNaviEdit (0)

Contact

Jose Godinho
Department of Analytics

Phone: +49 351 260 - 4475

Projects

3D X-ray Computed Tomography (3D X-ray CT)

To plan a CT experiment with our scanner, please use the following interactive user interface: https://ctplanning-prototype-v1p4.streamlit.app/


Technical Specifications

  • CoreTOM from XRE
  • Down to 5 micron voxel size
  • Fast in situ scans (<1 min.)
  • Energy range of the source: tungsten (40-180) keV
  • Power: up to 300 W
  • Normal detector size: 2880 x 2880
  • Prototype of a energy selective detector that allows resolving the energy spectrum of the transmitted X-rays (energy range: 23-155 KeV over 120 energy bins, resolution ~ 1.1 keV)

Application

  • Visualization of mineral distribution in a rock
  • Quantification and statistical analysis of the components inside a sample
  • 3D Rendering of materials to feed into numerical models
  • Analysis of time-lapse processes inside materials
  • 3D element / mineral identification by coupling the normal detector with the spectral detector

Sample Requirements

  • Samples up to 1 m height and 30 cm diameter
 
3D image of a REE (red) bearing carbonate rock ©Copyright: da Assuncao Godinho, Jose Ricardo

3D image of a REE (red) bearing carbonate rock (~15 cm diameter) 

Foto: J.R.A. Godinho

 
3D image of a crushed REE (red) bearing carbonate rock ©Copyright: da Assuncao Godinho, Jose Ricardo

Particles (<1 mm) from the same rock (left), after comminution

Foto: J.R.A. Godinho


EXCITE Project

Download video/mp4 - 113,2 MB / 1920x1080 px

The project brings together on a European scale key national and regional electron and X-ray microscopy facilities to European researchers, from both academia and industry, ensuring their optimal use and joint development.

To meet these aims, the project combines:

  • Networking activities, to foster a culture of co-operation between research infrastructures that aim to standardize procedures for multiscale imaging between different X-ray and electron beam techniques.
  • Trans-national access to key research infrastructures between the partners; Spectral-CT scanner will be the main instrument provided by HIF.
  • Standardize analysis and automation of data linkage between different techniques. Includes developing artificial intelegence methods.

Selected Publications ►

  •  Godinho, Jose R. A.; Westaway-Heaven, G.; Boone, M. A.; Renno, A. D. Spectral Tomography for 3D Element Detection and Mineral Analysis, Minerals, 11, 2021  DOI: 10.3390/min11060598
  • Godinho, J. R. A.; Kern, M.; Renno, A. D.; Gutzmer, J.
    “Volume quantification in interphase voxels of ore minerals using 3D imaging”, Minerals Engineering (2019)
    DOI-Link: j.mineng.2019.106016

How does it work? ►

The materials inside a sample are imaged based on the principle that each material attenuates X-rays differently, depending on its electron density. Radiographs are acquired while rotating the sample (360 degrees). The samples are then computationally reconstructed into a 3D image of the sample. Normal detectors measure the total amount of X-rays (of all energies), while our special energy sensitive detector allows to resolve the energy spectrum. This helps to identify elements with a k-edge > 23 keV (heavier than Ru).  

Important to plan a scan: The resolution is inversely proportional to the field of view. Samples < 2 cm diameter are necessary to achieve the highest resolution (~4 um). Cylindrical samples are ideal but other geometries can be measured without any special treatment. The method is non-destructive.